Peace of Mind:  PROVIDES A BETTER CHANCE OF SURVIVAL DURING EMERGENCIES

Without protection, 80 % of fire victims will die by
toxic smoke this year.

 
 
 
Peace of Mind Evacuation Hood

Peace of Mind Smoke Hood

Model # 52705:List Price:$49.90

Internet Price: $42.00

 

 


 
UHA International engineers have invested the past two years in developing the Peace of Mind evacuation hood. The P.O.M. evacuation hood increases your chances of surviving a fire or bacteriological emergency. It provides 20 minutes of breathable air allowing you precious time to evacuate.
Features and Benefits:
  • Filters smoke and bacteriological contaminants
  • Pocket size package
    (6" X 5" X ˝" 15cm X 12.5cm X 1.5 cm)
  • Easy to use
  • Clear see-through high heat resistant nylon film allows full range of vision
  • Filter adapts to any face
  • Reflective elements make user visible to rescuers
  • Glow in the dark inscription makes hood easy to find in the dark.
  • No mouth piece - allows user to communicate freely
  • Elastic neck band provides a snug fit and prevents smoke form entering hood.
     
Intended use: The Peace of Mind evacuation hood is intended to be used by the general public, fire departments, ambulance crews, government personnel and any frontline professional in the case of an emergency.

 

Technical Data
  • Filter: Meets NIOSH N99 standard
    (99.9% at .3 microns)
  • Fabric: Extensible laminated hydrophilic fabric
    (heat resistance: 480°F / 250°C)
  • Film : Clear nylon visor
    (heat resistance :400F / 205C)
  • Reflective Elements: ANSI/ISEA 107-1999 retro reflectivity
  • Shelf life: 5 years from date of manufacturing
     
Where to use The P.O.M.'s compact, lightweight format make it easy to store where it will be most easily accessible in case an emergency arises. Here are some suggestions:
At home: Night table
At work: Desk, briefcase, handbag, etc.
Travelling: In carry-on bag, pocket

 

                   
FILTRATION CAPACITIES                
                   
Substance Index   Substance Index   Substance Index   Substance Index
                   
Acetaldehyde * 2   Corrosive gases 3   Hexane 3   Nitric acid * 3
Acetic acid 4   Cresote 4   Hexylen 3   Nitro benzenes * 4
Acetic anhydride 4   Cresol 4   Hexyne * 3   Nitroethane 4
Acetone 3   Crotonaldehyde 4   Hydrogen 1   Nitrogen dioxide * 2
Acetylene * 1   Cyclohexane 4   Hydrogen bromide * 2   Nytroglycerine 4
Acrolein * 3   Cyclohexanol 4   Hydrogen chloride * 2   Nitromethane 4
Acrylic acid 4   Cyclohexanone 4   Hydrogen cyanide * 2   Nitropropane 4
Acrylonitrile 4   Cyclohexene 4   Hydrogen fluoride * 2   Nonane 4
Adhesives 4   Decane 4   Hydrogen iodide * 3   Octalene 4
Air-Wick 4   Dibromethane 4   Hydrogen selenide * 2   Octane 4
Amines * 2   Dichlorobenzene 4   Hydrogen sulfide * 3   Ozone 4
Ammonia * 2   Dichlorodifluomethane 4   Indole 4   Palmitic acid 4
Amyl acetate 4   Dichloroethane 4   lodine 4   Paradichlorobenzene 4
Amyl alcohol 4   Dichloroethylene 4   Isophorone 4   Pentane 3
Amyl ether 4   Dichloroethyl ether 4   Irritants 4   Pentanone 4
Anesthesics 3   Dichloromonofluormethane 3   Isoprene * 3   Pentylene * 3
Aniline 4   Dichloronitroethane 4   Isopropyl acetate 4   Pentyne * 3
Automobile exhaust 3   Dichloropropane 4   Isopropyl alcohol 4   Perchloroethylene 4
Borane 3   Dichlorotetrfluoroethane 4   Isopropyl ether 4   Phenol 4
Bromine 4   Diethylamine * 3   Kerosene 4   Phosgene 3
Butadiene 3   Diethyl ketone 4   Lactic acid 4   Propane 3
Butane 2   Dimethylaniline 4   Lysol 4   Propionaldehyde 3
Butonone 4   Dimethysulfate 4   Mercaptans 4   Propionic acid 4
Butyl acetate 4   Dioxane 4   Mesityl oxide 4   Propyl acetate 4
Butyl alcohol 4   Dipropylketone 4   Methane 1   Propyl alcohol 4
Butyl cellosolve 4   Ethane 1   Methyl acetate 3   Propyl chloride 4
Butyl chloride 4   Ether 3   Methyk acylate 4   Propyl ether 4
Butyl ether 4   Ethyl acetate 4   Methyl alcohol 3   Propyl mercaptan 4
Butylene * 2   Ethyl acrylate 4   Methyl bromide 4   Propylene * 3
Butyne * 2   Ethyl alcohol 4   Methyl buty ketone 4   Propyne * 2
Butyraldehyde * 3   Ethyl amine * 3   Methyl cellosolve 4   Pyridine 4
Butyric acid 4   Ethyl benzene 4   Methyl cellosolve acetate 4   Styrene monomer 4
Camphor 4   Ethyl bromide 4   Methyl chloride 3   Sulfur dioxide * 3
Caprylic acid 4   Ethyl chloride 3   Methyl Chloroform 3   Sulfur trioxide * 3
Carbolic acid 4   Ethyl ether 3   Methyl ether 3   Sulfuric acid 4
Carbon disulfide 4   Ethyl formate 3   Methyl ethyl ketone 4   Tear gas 4
Carbon dioxide * 1   Ethyl mercaptan 3   Methyl formate 3   Tetrachloroethane 4
Carbon monoxide 1   Ethyl silicate 4   Methyl isobutyl ketone 4   Tetrachloroethylene 4
Carbon tetrachloride 4   Ethylene * 1   Methyl mercaptan 4   Toluene 4
Cellosolve 4   Ethylene chlorhydrin 4   Methylcyclohexane 4   Toluidine 4
Cellosolve acetate 4   Ethylene dichloride 4   Methylcyclohexanone 4   Trichlorethylene 4
Chlorine 3   Ethylene oxide 3   Methylcyclohexanol 4   Trichloroethane 4
Chlorobenzene 4   Fluorotrichloromethane 3   Methyl chloride 4   Turpentine 4
Chlorobutadiene 4   Formaldehyde 2   Monochlorobenzene 4   Uric acid 4
Chloroform 4   Formic acid * 3   Monofluorotrichloromethane 4   Valeric acid 4
Chloronitropropane 4   Heptane 4   Naptha (coal tar) 4   Valericaldehyde 4
Chloropicrin 4   Heptylene 4   Naptha (petroleum) 4   Vinyl chloride 3
          Naphthalene 4   Xylene 4

Test Report J1727

      Laboratory:  ICS Laboratories Inc.                                                Object:   Peace of mind hood

                      1072 Industrial Parkway                                                                                                              3 layers filtration device

                               Brunswick, OH
                              
USA 44212

 

 

      Client: Textile Technology Centre           Date:  March 21,2003            
  3000, Boulle Street                                          Report:  J1727
  St-Hyacinthe, Quebec                                                                                 Issue:     1
  Canada J2S1H9

 

        On behalf :   UHA International Inc.

    18 rue Turgeon, suite 106

    Ste-Thérčsel, Québec

    Canada J7E 3H3

Initial Penetration / Resistance Profiles

Sample ID

 

Sampling Flow Rate (LPM)

 

Résistance (mm water)

 

NIOSH Limit (mm water)

 

Result

 

 

 

Penetration

(%)

 

NIOSH Limit for N99 (%)

 

Result

 

1-1

 

86.8

 

6.9

 

 

 

 

 

 

 

 

 

 

<=30,0

 

Pass

 

 

 

0.152

 

 

 

 

 

 

 

 

 

 

<=1,0

 

Pass

 

1-2

 

86.7

 

6.7

 

Pass

 

 

 

0.195

 

Pass

 

1-3

 

85.6

 

6.5

 

Pass

 

 

 

0.354

 

Pass

 

1-4

 

85.6

 

6.8

 

Pass

 

 

 

0.347

 

Pass

 

1-5

 

85.6

 

7.1

 

Pass

 

 

 

0.299

 

Pass

 

1-6

 

85.5

 

6.8

 

Pass

 

 

 

0.332

 

Pass

 

1-7

 

85.4

 

6.4

 

Pass

 

 

 

0.287

 

Pass

 

1-8

 

85.4

 

6.9

 

Pass

 

 

 

0.316

 

Pass

 

1-9

 

85.5

 

6.9

 

Pass

 

 

 

0.296

 

Pass

 

1-10

 

85.3

 

6.9

 

Pass

 

 

 

0.254

 

Pass

 

1-11

 

85.4

 

7.3

 

Pass

 

 

 

0.262

 

Pass

 

1-12

 

85.4

 

6.4

 

Pass

 

 

 

0.290

 

Pass

 

1-13

 

85.3

 

7

 

Pass

 

 

 

0.303

 

Pass

 

1-14

 

85.2

 

6.8

 

Pass

 

 

 

0.344

 

Pass

 

1-15

 

85.1

 

6.8

 

Pass

 

 

 

0.352

 

Pass

 

1-16

 

85.3

 

6.8

 

Pass

 

 

 

0.337

 

Pass

 

1-17

 

85.1

 

6.8

 

Pass

 

 

 

0.320

 

Pass

 

Conclusion:

The filtration efficiency of a 3 layer assembly was determined. The results shows that the filter media successfully conformed to the requirements for an N99 efficiency performance. Also, the efficiency of the filtration assembly for Sodium Chloride (NaCI) is N99 (% of particles penetration less than 1%) as NIOSH 42 CFR Part 84,181. Last, the assembly meets the performance criteria for air résistance specified by NIOSH 42 CFR Part 84,180 since it's résistance value is lower than 30 mm water

 

 

Smoke Hoods

Raytech carries a variety of smoke hoods to fit your needs!
   NEW!! Peace of Mind Evacuation Hood for Home, Office or Hotel.in the event of a fire or biological emergency, the Peace of Mind Evacuation Hood provides you with up to 20 minutes of filtered, breathable air free of smoke or biological contaminants. The compact, lightweight package can be stored anywhere. Meets NIOSH N99 standard. Effective against SARS!
 


Shipping and handling $5.00...add $1.00 for each additional unit...Bulk discounts, please call for quote

blue_lin.gif

AlpineAire | Bottom's Up | Kaptair Smoke Hoods | MRE | MSM | Survival and First Aid Kits | WaterOz | WaterOz Ozone Generator

Return to Health & Survival Main Menu

Home Fax/Mail Order E-Mail Order Secure Order
Copyright (c) Raytech, 2003, All rights reserved.
635 E. First Street, Suite 203, Tustin, CA 92780
E-mail: raytech@covad.net
Tel: (714) 544-8864   Fax: (714) 544-8120  Toll-Free: (800) 838-5898
HOME    ORDER    CONTACT    ABOUT RAYTECH    CONDITIONS OF SALE
We accept Visa, Master Card, American Express, Discover, Wire Transfer, Check, or Money Order.


Catalog Code: RCS